Principles of body fat percentage measurement  
The Tanita Body Fat Monitor/Scale TBF-604 allows you to estimate your body fat  
percentage at home as easily as you measure your weight.  
What is body fat percentage?  
Body fat percentage is the percentage of fat in your body. Until now, your absolute  
weight has determined whether or not you were considered overweight or obese. In  
recent years, the definition of obesity has been refined to mean the presence of excess  
body fat. Too much body fat has been linked to conditions such as high blood pressure,  
heart disease, diabetes, cancer, and other disabling conditions.  
1, 2  
Body Fat Ranges for Standard Adults  
Underfat  
Healthy  
Overfat  
Obese  
Female 20–39  
Age 40–59  
60–79  
0%  
10%  
20%  
30%  
40%  
Male 20–39  
Age 40–59  
60–79  
Underfat  
1 Based on NIH/WHO BMI Guidelines.  
2 As reported by Gallagher, et al., at NY Obesity Research Center.  
To determine the percentage of body fat that is appropriate for your body, consult your physician.  
Healthy  
Overfat  
Obese  
The BIA method  
The TBF-604 uses the BIA (Bioelectrical Impedance Analysis) technique. In this method,  
a safe low-level electrical signal is passed through the body. It is difficult for the signal to  
flow through fat in the human body, but easy to flow through moisture in the muscle  
and other body tissues. The difficulty with which a signal flows through a substance is  
called impedance. So the amount of fat in the body can be accurately estimated by meas-  
uring the impedance. The signal used is very low, making it safe and imperceptible.  
Tanitas patented foot-paddesign sends a safe,  
low-level electrical signal through the body to deter-  
mine its composition.  
The illustration on the left show how the signal travels through the body.  
Body fat percentage fluctuations in a day  
Hydration levels in the body may affect body fat readings. Readings are usually highest  
in the early waking hours, since the body tends to be dehydrated after a long nights  
sleep. For the most accurate reading, a person should take a body fat percentage reading  
at a consistent time of day under consistent conditions.  
Body Fat %  
22  
21  
20  
Besides this basic cycle of fluctuations in the daily body fat readings, variations may be  
caused by hydration changes in the body due to eating, drinking, menstruation, illness,  
exercising, and bathing. Daily body fat readings are unique to each person, and depend  
upon ones lifestyle, job and activities.  
19  
18  
17  
The graph on the left shows an example of daily body fat percentage fluctuations.  
Advantages of the Tanita TBF-604  
6am  
10am  
2pm  
6pm  
10pm Time  
Previously, body fat percentage was determined by measuring the thickness of subcuta-  
neous fat by pinching it with calipers, or by laying a person on a scanning bed and pass-  
ing a current from hand to foot. However, these methods had problems; measurement  
values varied, professional skills were required, and extensive time was required for  
measurement. Currently, the standard methods of fat percentage measurement are  
DEXA (dual energy x-ray absorptiometry) and Hydrodensitometry (underwater weigh-  
ing).  
Daily fluctuations in body fat percentage based  
on the BIA method  
Based on data from both the DEXA and underwater weighing methods, Tanita established  
a formula for estimating the percentage of body fat. There is a high correlation between  
measurements taken with the TBF-604 and those obtained through DEXA and underwa-  
2
ter weighing.  
 
Table of contents  
page  
1
2
Safety precautions  
Important notes for users  
Principles of body fat percentage measurement  
What is body fat percentage?  
Reasonable ranges of body fat percentage  
Body fat percentage measurement  
Body fat percentage fluctuations in a day  
Advantages of the TANITA Body Fat Monitor/Scale TBF-604  
4
6
7
Features and functions of TBF-604  
Components  
Measuring platform  
Accessories  
Useful features of the TBF-604  
Preparations before use  
Inserting the batteries  
Positioning the monitor  
Attaching the support feet  
Handling tips  
How to measure body fat percentage  
Overview of measuring  
Setting and storing data in memory  
Taking measurements  
Multiple users  
Replacing the batteries  
9
Troubleshooting  
Specifications  
10  
Warranty  
FEDERAL COMMUNICATIONS COMMISSION NOTICE  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and  
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particu-  
lar installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio or television technician for help.  
Modifications  
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Tanita Corporation may void the users  
authority to operate the equipment.  
3
 
TANITA TBF-604 BODY FAT MONITOR/SCALE  
Features and functions of the TBF-604  
Components  
Measuring platform  
(1)  
(4)  
(4)  
(1)  
(1)  
(1)  
Support feet  
AA-size batteries  
Instruction manual  
Warranty card  
Educational booklet  
Getting Started workbook (1)  
Measuring platform  
1. Display screen  
2. Blue Set button  
3. Green Arrow (select) button  
4. Toe electrodes  
5. Heel electrodes  
6. Guide marks sticker  
For positioning heels when standing on the unit.  
7. PERSONAL keys (start switch)  
Setting of adult male or female and height for two persons can  
be stored in the memory of the unit.  
1
2
3
4
6
7
5
4
 
Accessories  
8. Support feet (4)  
8
For use on carpeting 0.8 inch thick or less; a hard, uncarpeted surface  
is recommended.  
9. AA-size batteries (4)  
These are trial batteries; their service life will be short. New batteries will  
last for about a year if the unit is used every day.  
9
Useful features of the TBF-604  
The TBF-604 allows you to measure both weight and body fat percentage simultaneously  
as easily and simply as stepping on a scale.  
The TBF-604 can be set for an adult male or female, increasing the accuracy of  
the measurements.  
Personal data (gender and height) are stored in the memory of the unit.  
Switching the weight mode  
The TBF-604 can record measurements in lb (pounds), kg (kilograms), or st-lb (British  
stone pounds). To select the preferred mode, make sure the monitor is off. Press the  
Green Arrow and Blue Set buttons simultaneously. Press the Green Arrow button to  
choose your measurement mode (lb/kg/st-lb), then press the Blue Set button. The display  
screen will flash to confirm your selection and store it in memory. (To change weight  
mode, repeat the previous steps.)  
Automatic shut-down function  
The automatic shut-down function shuts off the power automatically in the  
following cases:  
If you interrupt the measurement process.  
The power will shut down automatically within 10 to 20 seconds, depending  
upon the type of operation.  
If an extraordinary weight is applied to the platform.  
If you make a mistake during measurement or a key operation.  
After you have completed the measurement process.  
NOTE: If the power shuts off automatically due to a problem, repeat the steps from the  
beginning (see pp. 7-8 for steps).  
5
 
TANITA TBF-604 BODY FAT MONITOR/SCALE  
Preparations before use:  
Inserting the batteries  
1. Locate the battery cover on the back of the monitor platform. Press the tab to release  
Open as shown  
the cover as shown.  
Direction of the batteries  
2. Insert the supplied AA-size batteries as indicated.  
NOTE: Be sure that the polarity of the batteries is set properly. If the batteries are  
incorrectly positioned the fluid may leak and damage floors. If you do not intend to  
use this unit for a long period of time, it is advisable to remove the batteries before storage.  
Positioning the monitor  
Place the monitor on a hard, flat surface where there is minimal vibration to ensure safe  
and accurate measurement.  
NOTE: To avoid possible injury, do not step on the edge of the platform.  
Attaching the support feet (carpet use only)  
Insert the support feet into the holes at the four corners on the bottom of the  
measuring platform.  
NOTE: Do not use the monitor on any carpeting that is more than 0.8 inch in thickness.  
Do not use the support feet on hard, flat surfaces, as the unit may tip over.  
Handling tips  
This monitor is a precision instrument utilizing state-of-the-art technology. To keep the  
unit in the best condition, follow these instructions carefully:  
Do not attempt to disassemble the measuring platform.  
Store the unit horizontally, and place it so that the PERSONAL key will not be  
pressed accidentally.  
Avoid excessive impact or vibration to the unit.  
Place the unit in an area free from direct sunlight, heating equipment, high humidity,  
or extreme temperature change.  
Never submerge in water. To clean, use a dampened cloth and mild detergent.  
Use alcohol to clean the electrodes.  
When you change the batteries, exchange all four batteries at the same time with new  
AA-size batteries.  
If you need assistance, please call our toll-free customer service number at 1-800-TANITA-8.  
6
 
How to measure body fat percentage  
Overview of measuring  
To get the most accurate absolute values, measurements should be taken while wearing  
no clothing, preferably in the evening, and after urinating. If you do not undress, always  
remove your socks or stockings, and be sure the soles of your feet are clean before step-  
ping on the measuring platform. Stand erect on the platform. If used after bathing, the  
body must be completely dry.  
NOTE: Accurate measurement will not be possible if the soles of your feet are not clean, or if  
your knees are bent or you are in a sitting position.  
It is best to take measurements at the same time each day, preferably in the evening. If  
doing so is not convenient, remember to wait about three hours after rising, eating, or  
hard exercise before taking measurements. While readings taken under other conditions  
may not have the same absolute values, they are accurate for determining the percentage  
of change as long as the readings are taken in a consistent manner. To monitor progress,  
compare weight and body fat percentage measurements taken under the same conditions  
over a period of time.  
Setting and storing data in memory  
The TBF-604 can be operated only if data has been pre-programmed. Once programmed,  
tapping the appropriate PERSONAL key turns the monitor on. The unit has an automatic  
shut-down function. If you do not step on the platform after pressing the PERSONAL  
key, the unit will automatically shut off in about 30 seconds.  
The TBF-604 is a Personal Model for male or female adults aged 18 or older.  
Turn the unit on.  
The TBF-604 is not intended for use by persons involved in intense aerobic exercise of at least 10 hours  
per week and who have a resting heart rate of less than 60 beats per minute. It is also not intended for  
professional athletes or bodybuilders who may experience physical changes due to dehydration.  
1. Turn on the power  
When programming data, use the Blue Set button to turn the unit on. The numbers  
(1 or 2) will appear and the display will flash.  
Select PERSONAL key.  
Install in memory.  
2. Select Personal key  
Use the Green Arrow button to select a PERSONAL key number for the person whose  
measurement is to be taken. Then press the Set button.  
3. Select Male or Female  
Use the Arrow button to select the appropriate gender, then press the Set button.  
Select gender.  
Install in memory.  
Install in memory.  
(
) Male  
(
) Female  
4. Specify the height  
Use the Arrow button to specify the height in feet and inches. Then press the Set button.  
Specify the height.  
The display will flash all data (adult male or female and height) for 3 seconds to confirm  
the programming. The power will automatically turn off.  
Confirmed data will flash for 3 seconds.  
 
TANITA TBF-604 BODY FAT MONITOR/SCALE  
Taking measurements  
1. Turn on the power  
Using your toe, turn the unit on by tapping the appropriate PERSONAL key located on  
the front of the measuring platform.  
NOTE: Do not hold the key down or the display will show “ error” and the programmed  
data will be erased and require resetting.  
Turn the unit on.  
Your pre-set data will appear (gender and height).  
Immediately after your pre-set data, the display will show 0.0 lb.  
Pre-set data will appear.  
Wait for 0.0 lbto appear.  
2. Take measurement  
Wait for 0.0 lbto appear before stepping onto the measuring platform.  
NOTE: If you step on before 0.0 lb, you will not receive a reading.  
Be sure you are barefoot, and that the soles of your feet are clean and dry.  
Be sure that your toes and heels are correctly aligned with the toe and heel electrodes on  
the measuring platform. Stand erect on the platform.  
Weight will appear first.  
NOTE: If you do not step onto the measuring platform within about 20 seconds after  
0.0 lbappears, the power shuts off automatically.  
Your weight will be shown first. The numbers 5, 4, 3, 2, 1 will appear one after another in  
the display. The numbers will disappear, and your body fat percentage will be displayed.  
Display counts down from 5 to 1.  
Continue to stand erect on the platform. The values of body fat percentage and body weight  
will be displayed alternately at 2-second intervals. If you remain on the platform, the display  
will continue for about 30 seconds, and then the power will automatically turn off.  
Body fat percentage will appear.  
If you step off the platform, the alternating display of body fat percentage and body  
weight will be repeated 3 times, and then the power will automatically turn off.  
Multiple users  
The unit may be used by more than two persons. Simply repeat the programming  
process. (Steps 1 through 4 of setting and storing data in memory.)  
Data will be repeated 3 times, then the power will  
automatically turn off.  
NOTE: Previously stored data will be erased.  
Replacing the batteries  
When the batteries run low, the Lomessage will appear on the display window. When  
this message appears, be sure to replace the batteries immediately, since weak batteries  
will affect the accuracy of your measurements.  
The batteries run low.  
Your setting will not be erased from the memory when you remove the batteries.  
New batteries will last for about one year if the unit is used once every day. The unit  
comes with trial batteries; their service life will be short.  
8
 
Troubleshooting  
If the following problems occur...  
Then...  
Check foot alignment. Make sure you wait for 0.0 lbto appear before stepping on the  
Nothing appears in the LCD after  
platform. Check to see that the batteries are fresh and are in the correct positions.  
initial display.  
Nothing appears when the PERSONAL key  
No data (gender or height) has been stored in the memory.  
is pressed, or  
The display shows - - - - -and goes off  
when the PERSONAL key is pressed.  
The body fat percentage measurement  
does not appear after the weight  
is measured.  
Vibration will interfere with measurement of the fat percentage. Be sure to stand erect  
and still on the measuring platform. Do not bend your knees. Be sure that shoes and  
socks are removed and check foot alignment. Step off and repeat steps on p.8.  
The body fat percentage measurement  
is extremely low.  
Be sure you are measuring in the correct user mode (male or female), and that the soles of  
your feet are clean and properly aligned with the guides on the measuring platform.  
Consider whether or not you are over-hydrated. Step off and repeat steps on p.8.  
The body fat percentage measurement  
is extremely high.  
Be sure you are measuring in the correct user mode (male or female), and that the soles  
of your feet are clean and properly aligned with the guides on the measuring platform.  
Dehydration, exercise, foot calluses, etc. will interfere with measurement of the fat per-  
centage. Step off and repeat steps on p.8.  
SPECIFICATIONS: TBF-604 BODY FAT MONITOR/SCALE  
Unit: lb  
300 lb  
Unit: st-lb  
21st-6lb  
Unit: kg  
136 kg  
Capacity  
0-300 lb / 0.5 lb  
0-136 kg / 0.2 kg 0-21st-6lb / 0.5lb  
Graduation  
Fat Percentage  
1.0%  
DC 6V AA-size (UM3-type) dry battery (x4) included  
Power Supply  
Power Consumption  
Measuring Current  
UPC No:  
After sales service  
Please contact the store at which you bought  
this monitor for any inquiry regarding opera-  
tion or trouble, request for repair and/or  
placement of an order for parts or products. Or  
call 1-800-TANITA-8 (USA and Canada only).  
60 mA maximum  
50 kHz 500 µA  
TBF-604-LG (Light Grey) 742496-860408  
Not for trade use.  
9
 
TANITA PRODUCTS LIMITED WARRANTY  
Not Valid Without Proof of Purchase  
Your Tanita product is warranted to the original consumer only, for one (1) year, to be free from defects in materials and work-  
manship under normal use. This product is designed for Personal use only. Tanita Corporation of America reserves the  
right to nullify the warranty agreement should the product be used in a commercial environment. This warranty is void if the  
product has been tampered with or mistreated, or if the defect is related to servicing or parts not supplied by us. Our obliga-  
tion under this warranty is limited solely to the charge of repairing the product, plus the cost of parts or, at the option of Tanita,  
replacing the product with an equivalent model. There are no express or implied warranties except as listed above. Tanita is  
not liable for incidental or consequential damages for failure or malfunction of the product and any recov-  
ery may not be greater than the purchase price paid for this product. Some states do not allow limitation on how  
long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above limitations  
may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state  
to state. No person is authorized to change the terms of this warranty.  
IF PRODUCT IS DEFECTIVE OR NEEDS REPAIR  
Do not return this product to the place of purchase; doing so may delay the processing of your warranty claim.  
Call Tanita at: 1-800-TANITA-8 to receive a Return Authorization Number before returning this product. Include $12.50 for  
handling, return postage and insurance to the facility listed below. Proof of purchase must accompany the product.  
Because of possible loss, we recommend insuring your product, return receipt requested, when using the mail. If you do not  
receive a receipt within a reasonable time, start a tracer through the originating post office. It is important that you pack the  
product carefully prior to shipment to prevent damage in transit and that you include a letter describing in detail the specific  
condition requiring adjustment or repair.  
TANITA PRODUCTS LIMITED AFTER WARRANTY  
All terms and conditions apply as specified above in the original Tanita Limited Warranty except for the cost of labor and parts:  
Minimum charge for After Warranty labor is $30 per hour, plus the cost of parts.  
You will be notified by mail or telephone of the total cost to repair your product to working condition, so prepayment can  
be arranged.  
Your approval is required before any repair work can be performed on your product.  
Please complete the following information and retain for your records.  
MODEL:  
DATE PURCHASED:  
/
/
PURCHASED FROM:  
ADDRESS:  
Please send all returns to:  
Tanita Corporation  
2625 S. Clearbrook Drive  
Arlington Heights, IL 60005 USA  
AStepToward A Healthier Life.  
10  
 
©1998 Tanita Corporation All rights reserved 6/98 HDI  
TANITA Corporation  
TANITA Corporation of America Inc.  
2625 S. Clearbrook Drive  
Arlington Heights, IL 60005 USA  
Tel. 847-640-9241 Fax 847-640-9261  
Toll Free 1-800-TANITA-8  
http:// WWW.TANITA.COM (English)  
http:// WWW.TANITA.CO.JP (Japanese)  
14-2, 1-Chome, Maeno-Cho  
Itabashi-Ku, Tokyo, Japan  
Tel. 03-3968-2123 Fax 03-3967-3766  
ISO 9001 Certified  
TANITA UK Ltd.  
TANITA France S.A.  
3-3 Bis, Rue Charcot 92200  
Neuilly-sur-Seine, France  
Tel. 01-5524-9999  
TANITA Health Equipment H.K. Ltd.  
Unit 301-303 3/F Wing On Plaza  
62 Mody Road, Tsimshatsui East  
Kowloon, Hong Kong  
TANITA Europe GmbH  
Dresdener Strasse 25  
D-71065 Sindelfingen, Germany  
Tel. 07031-61896  
Tanita House, Willow Avenue, Denham  
Uxbridge, Middlesex UB9 4AF, Great Britain  
Tel. 01895-232355  
Fax 01895-233116  
Fax 01-5524-9868  
Tel. 852-2838-7111 Fax 852-2838-8667  
Fax 07031-618971  
 

Sennheiser Stereo Receiver GA 19 User Manual
Servis Rhino Lawn Mower 00781400C User Manual
Sharp Fax Machine UX B20 User Manual
Shure DJ Equipment SCM262 User Manual
Sonance Speaker C201SQ User Manual
Sony Car Stereo System CDX GT41UW User Manual
Sony CD Player PDW 1500 User Manual
Sony Speaker DAV JZ8888K User Manual
Speco Technologies Portable Speaker SP RK65CB T User Manual
Sunbeam Microwave Oven SMW714 User Manual